25-30W, Wide Input Range, Single Output DC/DC Converters
Key Features
¡EEfficiency up to 88%
¡E1500VDC Isolation
¡EMTBF > 600,000 Hours
¡E2:1 Wide Input Range
¡ECSA60950-1 Safety Approval
¡EComplies with EN55022 Class A
¡ESix-Sided Shielding
¡ERemote On/Off Control
¡ESoft Start
¡EOver Voltage Protection
¡EOutput Trim
 
  Selection Guide
Model Number
nput Voltage
Output Voltage
OutputCurrent
Efficiency
Reflected Ripple Current
Over Voltage Protection
VDC
VDC
mA
% Typ.
mA Typ.
VDC
MKW5030
24
( 18 ¡V 36 )
2.5
6000
84
100
3
MKW5031
3.3
6000
86
3.9
MKW5032
5
5000
88
6.8
MKW5033
12
2500
88
15
MKW5034
15
2000
88
18
MKW5039
5.1
5000
88
6.8
MKW5040
48
( 36 ¡V 75 )
2.5
6000
84
50
3
MKW5041
3.3
6000
86
3.9
MKW5042
5
5000
88
6.8
MKW5043
12
2500
88
15
MKW5044
15
2000
88
18
MKW5049
5.1
5000
88
6.8
     
 

Minmax's MKW5000-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 18-36VDC and 36-75VDC which provide precisely regulatedoutput voltages of 2.5V, 3.3V, 5V, 5.1V, 12V and 15VDC, specially addressing data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems.

Packing up to 30W of power into a 2x1x0.4inch package, with efficiencies as high as 88%, the MKW5000 includes continuous short circuit protection, overvoltage protection, output trim function, remote on/off, six-sided shielded case and EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering.

  Mechanical Dimensions
Pin Connections
 
Pin
Function
1
+Vin
2
-Vin
3
Remote On/Off
4
+Vout
5
-Vout
6
Trim
 
Case Size ¡V
50.8x25.4x10.2mm (2.00x1.00x0.40inch)
Case Material ¡V
Aluminum Anodizing Treatment in Black
Weight ¡V 32.0g (1.13Oz)
 
Tolerance
Millimeters
Inches
 
X.X¡Ó0.25
X.XX¡Ó0.01
 
X.XX¡Ó0.13
X.XXX¡Ó0.005
Pin
¡Ó0.05
¡Ó0.002
 
 
 
 
 
 
 
Absolute Maximum Ratings
Parameter
Min.
Max.
Units
Input Surge Voltage (1000mS)
24VDC Input Models
-0.7
50
VDC
48VDC Input Models
-0.7
100
VDC
Lead Temperature
(1.5mm from case for 10sec.)
---
260
¢XC
Internal Power Dissipation
---
5500
mW
Exceeding the unit absolute maximum ratings could cause damage.These are not continuous operating ratings.
 
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation Voltage
60 Seconds
1500
---
---
VDC
Isolation Resistance
500VDC
1000
---
---
M£[
Isolation Capacitance
100kHz, 1V
---
1200
1500
pF
Switching Frequency
280
350
400
kHz
MTBF
MIL-HDBK-217F @25¢XC Ground Benign
0.6
---
---
MHrs
 
Environmental Characteristics
Parameter
Conditions
Min.
Max.
Units
Operating Temperature
Ambient
-40
+50
¢XC
Operating Temperature
Case
-40
+105
¢XC
Storage Temperature
-50
+125
¢XC
Humidity
---
95
%
Cooling
Free-Air Convection
Conducted EMI
EN55022 Class A
RFI
Six-Sided Shielded, Metal Case
 
Output Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Line Regulation
Vin = Min. to Max.
---
¡Ó0.5
¡Ó1.0
%
Load Regulation
2.5V/3.3V/5V/5.1V
12V/15V
 
Io=0% to 100%
Io=10% to 100%
 
---
---
 
¡Ó0.5
¡Ó0.5
 
¡Ó1.0
¡Ó1.0
 
%
 
Ripple & Noise
20MHz BW
---
75
100
mV P-P
Short Circuit
Continuous
 
Maximum Capacitive Load
Models by Output Voltage
2.5V, 3.3V, 5V, 5.1V
12V & 15V
Units
6800
680
uF
   
Remote On/Off Control
Parameter
Min.
Max.
Units
Supply On
2.5 to 100VDC or Open Circuit
Supply Off
-1
1
VDC
Control Common
Referenced to Negative Input
Output Voltage Trim
Parameter
Conditions
Min.
Typ.
Max.
Units
Trim Up/Down Range
% of nominal
output voltage
¡Ó9.0
¡Ó10.0
¡Ó11.0
%
     
Derating Curve
 
 
Notes :
1. Specifications typical at Ta=+25¢XC, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a load step change of 75% to 100%.
3. These power converters require a minimum output load to maintain specified regulation.
4. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
5. All DC/DC converters should be externally fused at the front end for protection.
6. Other input and output voltage may be available, please contact factory.
7. To order the converter with Remote On/Off function, please add a suffix -RC (e.g. MKW5030-RC).
8. To order the converter with EN55022 Class A function, please add a suffix A (e.g. MKW5030A).
9. All specifications subject to change without notice.
 
 
Designed by Minmax / MSIE5.0 or NS6.2 above / 800 x 600 high color Copyright c 2005 Minmax Technology Co., Ltd.