Taking up as little
as 0.16 square inches of board space, Minmax's MFU100 1W DC/DC's are specially
designed to provide power distribution applications where space is critical
in an ultra-miniature DIP package. The series consists of 12 models with input
voltages of 5V, 12V and 24VDC which offers standard single output voltages of
5V, 9V, 12V, 15VDC. The MFU100 series is an excellent selection for a variety
of applications including distributed power systems, mixed analog/digital subsystems,
portable test equipments, local power networks and battery backed systems.
Mechanical
Dimensions
Pin Connections
Pin
Function
1
-Vin
4
+Vin
5
+Vout
7
-Vout
Case
Size ¡V
5V & 12V Input
¡V 12.7x7.0x10.16mm
(0.50x0.28x0.40 inches)
24V Input ¡V 12.7x8x10.16mm
(0.50x0.31x0.40 inches)
Case
Material ¡V
Non-Conductive
Black Plastic
Weight ¡V
5V & 12V Input ¡V 1.3g (0.05Oz)
24V Input¡V 1.7g (0.06Oz)
Tolerance
Millimeters
Inches
X.X¡Ó0.25
X.XX¡Ó0.01
X.XX¡Ó0.13
X.XXX¡Ó0.005
Pin
¡Ó0.05
¡Ó0.002
Absolute
Maximum Ratings
Parameter
Min.
Max.
Units
Input Surge Voltage (1000mS)
5VDC Input Models
-0.7
7
VDC
12VDC Input Models
-0.7
15
VDC
24VDC Input Models
-0.7
28
VDC
Lead Temperature (1.5mm from case for 10sec.)
---
260
¢XC
Internal Power Dissipation
---
450
mW
Exceeding the
unit absolute maximum ratings could cause damage. These are not continuous operating
ratings.
General
Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation
Voltage Rated
60 Seconds
3000
---
---
VDC
Isolation Voltage Test
Flash Tested for 1 Second
3300
---
---
VDC
Isolation Resistance
500VDC
1000
---
---
M£[
Isolation
Capacitance
100kHz, 1V
---
60
100
pF
Switching Frequency
50
90
110
kHz
MTBF
MIL-HDBK-217F @25¢XC Ground Benign
2000
---
---
K Hrs
Environmental
Characteristics
Parameter
Conditions
Min.
Max.
Units
Operating Temperature
Ambient
-40
+75
¢XC
Operating Temperature
Case
-25
+90
¢XC
Storage Temperature
-40
+125
¢XC
Humidity
---
95
%
Cooling
Free-Air Convection
Output
Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Output
Voltage Accuracy
For
Vin Change of 1%
---
¡Ó1.0
¡Ó3.0
%
Line Regulation
For Vin Change of 1%
---
¡Ó1.2
¡Ó1.5
%
Load Regulation
Io = 20% to 100%
See
Model Selection Guide
mV
P-P
Ripple
& Noise(20MHz)
---
100
150
mV
P-P
Ripple
& Noise(20MHz)
Over Line,Load Temp.
---
---
200
mV
P-P
Ripple
& Noise(20MHz)
---
---
5
mV rms
Over Load-
120
---
---
%
Temperature
Coefficient
---
¡Ó0.01
¡Ó0.02
%/¢XC
Output Short Circuit
0.5 Second Max.
Maximum
Capacitive Load
Models
by Output Voltage
5V
9V
12V
15V
Unit
Maximum Capacitive Load
33
33
33
33
uF
Derating
Curve (5V Output)
Notes
:
1.
Specifications typical at Ta=+25¢XC, resistive load, nominal input voltage, rated
output current unless otherwise noted.
2.
Ripple & Noise measurenent bandwidth
is 0-20 MHz.
3.
These
power converters require a minimum output load to maintain specified regulation.
4.
Operation
under no-load conditions will not damage these modules; however, they may not
meet all specifications listed.
5.
All DC/DC converters should be externally fused
at the front end for protection.
6.
Other
input and output voltage may be available, please contact factory.
7.
specifications subject to change
without notice.
Derating
Curve (Other Outputs)
Designed
by Minmax / MSIE5.0 or NS6.2 above / 800 x 600 high color Copyright c 2005 Minmax