5W, Wide Input Range SMD, Single & Dual Output DC/DC Converters
Key Features
¡EEfficiency up to 85%
¡E1500VDC Isolation
¡EMTBF >1,000,000 Hours
¡E2:1 Wide Input Range
¡EHigh Power Density
¡ERemote On/Off Control
¡EShort Circuit Protection
¡EComplies with EN55022 Class A
¡EUL 94V-0 Package Material
¡EInternal SMD Construction
 
  Selection Guide
Model Number
Input Voltage
Output Voltage
Output Current
Efficiency
Reflected Ripple Current
VDC
VDC
mA Max
mA Min.
% Typ.
mA Typ.
MSKW2021
12
( 9 ¡V 18 )
3.3
1200
120
76
25
MSKW2022
5
1000
100
80
MSKW2023
12
417
41.7
83
MSKW2024
15
333
33.3
83
MSKW2025
¡Ó5
¡Ó500
¡Ó50
80
MSKW2026
¡Ó12
¡Ó208
¡Ó20.8
83
MSKW2027
¡Ó15
¡Ó167
¡Ó16.7
83
MSKW2031
24
(18 ¡V 36)
3.3
1200
120
78
15
MSKW2032
5
1000
100
82
MSKW2033
12
417
41.7
85
MSKW2034
15
333
33.3
85
MSKW2035
¡Ó5
¡Ó500
¡Ó50
82
MSKW2036
¡Ó12
¡Ó208
¡Ó20.8
85
MSKW2037
¡Ó15
¡Ó167
¡Ó16.7
85
MSKW2041
48
(36 ¡V 57)
3.3
1200
120
78
10
MSKW2042
5
1000
100
82
MSKW2043
12
417
41.7
85
MSKW2044
15
333
33.3
85
MSKW2045
¡Ó5
¡Ó500
¡Ó50
82
MSKW2046
¡Ó12
¡Ó208
¡Ó20.8
85
MSKW2047
¡Ó15
¡Ó167
¡Ó16.7
85
     
 

Minmax's MSKW2000 5W DC/DC's are in "gull-wing" SMT package and meet 245oC/10sec in solder-reflow for lead free process.

The series consists of 21 models that operate over input voltage ranges of 9-18VDC, 18-36VDC and 36-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V,¡Ó5V, ¡Ó12V and ¡Ó15VDC.

The -40¢XC to +71¢XC operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems.

The modules have a maximum power rating of 5W and a typical full-load efficiency of 85%, remote on/off control, EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering.

 

  Mechanical Dimensions
Pin Connections
 
Pin
Singles
Duals
1
Remote On/Off
2
-Vin
-Vin
3
-Vin
-Vin
9
NC
Common
10
NC
NC
11
NC
-Vout
12
NC
NC
13
NC
NC
14
+Vout
+Vout
15
NC
+Vout
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
24
NC
NC
                    
NC: No Connection
 
 
 
 
 
 
 
 
 
Absolute Maximum Ratings
Parameter
Min.
Typ.
Max.
Units
Input Surge Voltage (1000mS)
12VDC Input Models
-0.7
---
25
VDC
24VDC Input Models
-0.7
---
50
VDC
48VDC Input Models
-0.7
---
100
VDC

Lead Temperature
(1.5mm from case for 10sec.)

---
---
260
¢XC
Internal Power Dissipation
---
---
2500
mW
Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings.
 
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation Voltage
60 Seconds
1500
---
---
VDC
Isolation Resistance
500VDC
1000
---
---
M£[
Isolation Capacitance
100kHz, 1V
---
650
750
pF
Switching Frequency
200
260
350
kHz
MTBF
MIL-HDBK-217F, @25¢XC Ground Benign
1
---
---
MHrs
 
Environmental Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Operating Temperature
Ambient
-40
---
+71
¢XC
Operating Temperature
Case
-40
---
+90
¢XC
Storage Temperature
-40
---
+125
¢XC
Humidity
---
---
95
%
Cooling
Free-Air Convection
Conducted EMI
EN55022 Class A
Remote On/Off Control
Parameter
Min.
Typ
Max.
Units
Supply On
2.5 to 5.5VDC or Open Circuit
Supply Off
-0.7
---
0.8
VDC
Control Common
Referenced to Negative Input

Physical Characteristics
Case Size
33.4x20.6x10.2mm(1.31x0.81x0.40inch)
Weight
14g(0.49Oz)
Case Material
Non-Conductive Black Plastic

 

 
Output Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage Accuracy
---
¡Ó0.5
¡Ó1.0
%
Line Regulatino
Vin = Min. to Max.
---
¡Ó0.1
¡Ó0.3
%
Load Requlation
Io = 20% to 100%
---
¡Ó0.3
¡Ó0.3
%
Ripple & Noise
20MHz BW
---
50
85
mV P-P
Output Short Circuit
Continuous

Maximum Capacitive Load
Models by Output Voltage
(Each Output on Duals)
Singles
Duals
Units
680
100
uF
 
 
     
Derating Curve
 
Notes :
1. Specifications typical at Ta=+25¢XC, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a load step change of 75% to 100%.
3. These power converters require a minimum output load to maintain specified regulation.
4. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
5. All DC/DC converters should be externally fused at the front end for protection.
6. Other input and output voltage may be available, please contact factory.
7. All specifications subject to change without notice.
8. For detailed data sheet, please visit our website.
 
Designed by Minmax / MSIE5.0 or NS6.2 above / 800 x 600 high color Copyright c 2005 Minmax Technology Co., Ltd.